Refractive index
A higher index bends light more, so the same prescription can be ground thinner. Gains are most visible in stronger minus powers.
Eyeglasses and Optical · Lens Materials
The material sets how thin, light, sharp and impact-resistant a pair of glasses can be.

How materials differ
Knowing the trade-offs between index, Abbe value and weight lets your opticians recommend with confidence and explain the price difference in one sentence. The trade-offs are the same in optometry and ophthalmology opticals.
Every lens material can be described by a few properties. Index drives thickness, Abbe value drives off-axis clarity, specific gravity drives weight, and impact behavior drives where the lens can safely be used.
A higher index bends light more, so the same prescription can be ground thinner. Gains are most visible in stronger minus powers.
Higher Abbe means less chromatic aberration. CR-39 sits near 58, while polycarbonate sits near 29 to 30, which some wearers notice as color fringing toward the edge.
Density in grams per cubic centimeter. Trivex is about 1.11 and polycarbonate about 1.21, compared with roughly 2.5 or more for glass.
Polycarbonate and Trivex are the go-to materials when impact protection matters. Trivex also holds up well in drilled rimless mounts.
Vision correction paths
Refractive error can be corrected with eyeglasses, contact lenses or refractive surgery, and opticals operate in optometry and ophthalmology practices alike. Vision Rescue does not rank these paths; the treating doctor and the patient choose based on the eyes, the prescription and how the patient lives. See the contact lens guide and the surgical co-management guide.
Refractive error is measured during a comprehensive eye exam, which also checks eye health before any correction is chosen.
Optometrists and ophthalmologistsAfter a refraction, the FTC Eyeglass Rule requires the prescriber to give the patient a copy of the prescription.
Prescribed by ODs and MDs; dispensed by opticians in optometry practices, ophthalmology practices and retailThe FTC Contact Lens Rule requires prescribers to release the prescription once the fitting is complete.
Fitted by optometrists and ophthalmologistsLASIK, PRK and related procedures reshape the cornea; the NEI describes LASIK as the most common type.
Ophthalmic surgeons, with pre- and post-op care often co-managed by an OD or MDLenses placed in front of or behind the iris while the natural lens stays in place; FDA-approved phakic lenses correct myopia.
Implanted by ophthalmic surgeonsA short decision path keeps the conversation simple at the dispensing table.
Index around 1.58 to 1.59 with Abbe near 29 to 30. Strong impact resistance; it can stress-crack in drill mounts, so check the lab and frame guidance.
Index 1.53, Abbe about 45 to 46, specific gravity 1.11. Lightweight and tough, with high tensile strength that suits drilled rimless frames.
Mitsui Chemicals lists MR-8 at 1.60 and Abbe 41, MR-7 and MR-10 at 1.67 and Abbe 31, and MR-174 at 1.74 and Abbe 32.
Crown glass offers about 1.52 index and Abbe near 59 but is heavy, and in the US it must be treated and tested to meet the federal impact rule.
At the dispensing table
The goal is to recommend one material clearly, explain why, and show the visible benefit rather than reading out a spec sheet.
Strong powers, large eyesizes and rimless mounts narrow the field before lifestyle is even discussed.
Thinner lenses can mean a lower Abbe value. For a patient sensitive to peripheral blur, a mid-index option may serve better than the thinnest one.
Higher-index lenses reflect more light at each surface, so anti-reflective treatment becomes part of the material recommendation.
| CR-39 (standard plastic) | Index 1.50 · Abbe 58 · SG 1.32 |
|---|---|
| Trivex | Index 1.53 · Abbe 45–46 · SG 1.11 |
| Polycarbonate | Index 1.58–1.59 · Abbe 29–30 · SG 1.21 |
| 1.60 (MR-8) | Index 1.60 · Abbe 41 (Mitsui) |
| 1.67 (MR-7 / MR-10) | Index 1.67 · Abbe 31 (Mitsui) |
| 1.74 (MR-174) | Index 1.74 · Abbe 32 (Mitsui) |
| Crown glass | Index 1.52 · Abbe 59 · SG 2.54 |
| 1.70 glass | Index about 1.71 · Abbe 35 · SG 3.20 |
Values are representative figures published by the material maker or an independent optical laboratory and vary slightly by supplier and measurement method. Confirm the exact material and its properties with your lab when ordering.
Not always. Higher index makes a thinner lens but usually lowers the Abbe value and raises reflections, so the best fit depends on the prescription, frame and patient.
Both are the impact-resistant choices. Trivex is lighter and has a higher Abbe value; polycarbonate is widely available and slightly thinner at the same power.
Polycarbonate is susceptible to stress cracks around drill holes. Trivex has high tensile strength, which is why many labs prefer it for rimless work.
In published laboratory data, polycarbonate, Trivex and the MR high-index materials transmit essentially no UV, while untreated CR-39 lets a small share through.
Yes, mainly for patients who want its scratch resistance and optics, but it is heavier and must meet the federal impact rule after treatment.
Opticals in ophthalmology practices dispense the same materials as optometry opticals, from polycarbonate and Trivex for impact resistance to high-index for strong prescriptions.
A clear material recommendation makes every other lens decision easier to explain, for any prescriber.